Figure 29 Diagnostic IDx, Alarms, and Filters Window
ID Entry and List
Allows the entry of a Long ID to be added to the ID List. The range of this field is 1 to 4294967295 but multiples of 1024
should not be used. A multiple of 1024 results in a Short ID of 0. If the Long ID is within the range of 1 to 1023, the
Short ID will be the same or the resulting Short ID will be smaller than the Long ID and will be represented by a “+
character in front of the ID. A Long ID is added to the ID List by an Enter or by clicking the Add ID button.
ID List: Allows the user to select a Long ID from the list to delete. A Long ID is deleted from the list by clicking the
Delete ID button.
Short ID: Shows the converted Short ID from the selected Long ID of the ID List.
Alarms and Filters
Alarms and Filters are used with Online Diagnostics. When Online Diagnostics are received and a diagnostic field falls
outside the Alarm limits, a “<”character will designate a value less than the low Alarm and a “>” character will
designate a value greater than the High Alarm.
When Online Diagnostics are received and a diagnostic field falls outside the Filter Limits, the diagnostic information is
considered invalid and is not displayed.
Low/High RSSI: Represents the low and high limits for the RSSI diagnostics (in dBm).
Low/High Temp: Represents the low and high limits for the temperature diagnostics (in degrees C).
Low/High Batt: Represents the low and high limits for the battery voltage diagnostics (in volts).
Low/High Fwd Pwr: Represents the low and high limits for the forward power diagnostics (in watts).
Low/High Rev Pwr: Represents the low and high limits for the Reverse Power diagnostics (in watts).
Open
The Open button allows the user to restore Diagnostics IDs, Alarms and Filters from a previously saved file.
Guardian™ Serial Modem or Analog Radio for Licensed Spectrum PN 001-5006-000 Rev. 3 | Page 43